Shorya Ventilator
Category: Global Medicare
Related products
5L Home Use Oxygen Concentrator
Specification 1. Oxygen flow rate : 1-5LPM/MIN 2. Oxygen Concentration : 93%+3% 3. Outlet pressure : 8.5-13 psi 4. Voltage : 230V;50hz 5. Power Consumption : 320W 6. Noise :<48dB(A) 7. Wight : 16 KG. 8. Nozzle : 1 9. Size : 305mm (L) x330 mm (W) x 535 mm (H) Function 1. Running time control & calculation 2. Alarms for high/low pressure, power failure and Gas blockage. 3. Protection for over-heat and over-load. 4. Purity alarm when the oxygen purity below 82% (Optional) 5. Medical nebulization by output oxygen dual Output.
Anesthesia Ventilator
Respiration mode - IPPV / Manual I:E ratio - 4:1- 1:6 Tidal Volume - 50ml ~1600ml Respiratory frequency - 1~90bpm PEEP - NO Waveform - NO Patient type - Adult, pediatric Display - High light LED display Driven mode - Pneumatically driven electronically controlled Gas supply - O2 or Medical Air Gas Supply pressure - 0.27-0.55 MPa Monitor parameter Tidal volume Minute ventilation Breath frequency I:E ratio Alarm Tidal volume high alarm Tidal volume low alarm Minute ventilation high alarm Minute ventilation low alarm
Automated External Difibrillator (AED)
Highlights * Special Impendance compensation technology * Unique human body resistance measurement * Reliable design for data security Reliable Technology for Life Saving Every Year SAC (Sudden Cardiac Arrest) threats lives of millions of people globally. it can happen to anyone at any time. an easy operation and reliable technology is vital for life saving. We are always ready. for every brilliant life in the world. Automated External Difibrillator (Automated External Difibrillator) a professional biphasic defibrillator is lightweight and compact size design and can be used in different situations, which is always ready for life saving. Key Features * Waveform : biphasic Truncated exponential * Mode : adult mode and optional pediatric mode * Prompts : voice prompts in the whole process * Particle and water Ingress : IPSS Battery installed) * Data transmission by infrared adapter * Daily and monthly self-test.
Endoscopy LED Light Source
1. High brightness is comparable to 350W traditional xenon light source, could be used for laparoscopy without any problem. 2. Long life, it could last 60000 hours max, 120times of xenon, so you do not need to replace the bulb for years. 3. Wide range power from 100-240V/AC; 50/60 Hz. 4. Perfect color temperature 600K to 6500K, color rendering is over 70. 5. Does not emit light in U or IR. 6. Customized connector, it accepts fiber light guides with active areas ranging from 3 mm to 10 mm diameter. 7. It saves energy for more than 50%. 8. Environmentally friendly. 9. Friendly design, easy operation
Fetal Doppler
Instructions Sonoline B Pocket Fetal Doppler is a hand-held obstetrical unit, which can be used in hospital, clinic and home for daily self-check by pregnant woman. Fetal doppler Contains components of ultrasonic signal transmitter and receiver, analog signals processing unit, FHR calculating unit, LCD display control unit etc. Sonoline B Pocket Fetal Doppler is a high performance model with (fetal heart rate) LCD digital display. It has 3 work modes: Real-time FHR display Mode, averaged FHR display mode, and manual mode. It has audio output and can be connected with earphone or recorder with audio input. Main Features -Battery status indicator -Low power inspection of the battery -Built-in speaker -Output for headphones -The probe can be changeable -Probe inspection -Backlight -Auto shut off -Support 2MHz, 3MHz, 4MHz, 5MHz, 8MHz probes -Two pieces of standard 1.5V alkaline battery available which can work no less than 10 hours Main performance. Anti-electroshock Type: Internally powered equipment 2.Anti-electroshock Degree: Type B applied part 3.LCD Display: 45 mm × 25 mm 4.FHR Measuring Range: 50 BPM ~ 240 BPM (BPM: Beat per minute) 5.Resolution: 1 BPM 6.Accuracy: ± 2 BPM 7.Power Consumption: < 0.8 W 8.Voltage: DC 3.0 V 9.Power Supply: TWO 1.5V(AA size)alkaline battery 10.Suitable Using Range: Suitable for use after the 12th week of pregnancy 11.Auto Shut-OFF: After 1 minute no signal, power off automatically Pocket Fetal doppler Probe: 1.Nominal Frequency: 2.0 MHz 2.Working Frequency: 2.0 MHz ± 10% 3.Ultrasound Output Power: P < 10 mW 4.Ultrasonic Output Intensity: Isata < 5 mW/cm2 5.Negative Peak Sound Pressure: P_ < 0.5 MPa 6.Working Mode: Continuous wave doppler Effective Radiating Area of Transducer: 208 mm2 ± 15% Physical Characteristic Dimension: (L) 135 mm × (W) 95mm × (H ) 35 mm Qualification Sonoline B:Pocket Fetal Doppler-CE/FDA
Transport Ventilator
BAMC Transport Pro 510s
Adult, Child, Infant (>3.5 kg) A/C-V with Sigh SPONT/PSV Apnea back-up ventilation
A/C-P CPAP Manual breath 0-2000 mL 0-50 cmH2O 0-30 cmH2O 2-30 L/min 4:1-1:10 40-100 % F-T
n510S is a universally used model. Not only for emergency ventilation, but also it is suitable for ideal transport ventilation. The circumstances include on-site emergency treatment, pre-hospital transport, inter- hospital transport, and even intra-hospital transport.
Reviews
There are no reviews yet.