BAMC Medical India…
BAMC Medical Ltd
MEDICAL PARK HARYANA
  • Home
  • Products
  • About Us
  • Contact Us
WELLMEDICA SKILL DEVELOPMENT CENTRE
Search
Menu
BAMC Medical Ltd
0 items ₹0.00
infant warmers bamc medical ltd panipat
Click to enlarge
infant warmers bamc medical ltd panipat
Home Global Medicare Infant Warmer
shorya plus icu ventilators bamc medical ltd panipat
Shorya Plus ICU Ventilator
Back to products
psg machine bamc medical ltd
PSG Machine

Infant Warmer

OPERATING MODES

  • SKINMODE:

In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.

· AIR MODE:

In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.

· MANUAL: MODE

In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 10

Compare
Add to wishlist
Category: Global Medicare
Share:
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

DISPLAY INDICATION

  • LCD:

LCD displays the following information.

  1. CurrentMode
  2. Heatingspeed
  • Alerts:Low Temp, High Temp, Probe fail
  1. Settings:Set Temp, Low Alarm, High Alarm, Manual mode timer, Calibration, Product branding
  2. APGARtimer

· 7 SEGMENT DISPLAY:

Displays current Skin and Air temperature, blinks for out of range (Low and high alarm) and clears upon probe fail.

ALERTS

  • Powerfail: Power fail indicator turns ON with sound alert (cannot be muted).
  • Probefail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp
  • Heateroverload: Heater overload indicator turns
  • Low temperature:Low alarm indicator turns ON with sound alert (can be muted). Displays
  • Hightemperature: High alarm indicator turns ON with sound alert (can be muted). Displays
  • Manualmode Time out: Short sound alert and timer flashing on

IMPORTANT INSTRUCTIONS

We recommend that you read the following instruction carefully, before using the machine/Equipment

  • Supplyvoltage should be between 220V-240V
  • Donot use the machine/Equipment when the mains cord, the plug or other components are damaged.
  • Themachine/Equipment should be handled by authorized person
  • Donot clean machine/Equipment with water or other cleaning
  • Checkheater and probe before using the
  • Donot leave baby unattended for long
  • Werecommend to use 650W
  • Newprobes or replacement probe should be calibrated before

Neonatal Pulse Oximeter/optional:

Pcb Design : BAMC Medical

Display  : 2” colour TFT

SpO2 measurement range 35%~100%
SpO2 measurement Accuracy ±2%(70%~100%)
SpO2 resolution 1%
PR measurement range 30~250bpm
PR measurement Accuracy The greater of ±2bpm
PR resolution 1%
Low perfusion performance 0.025%
Oximeter accuracy of ±2% and pulse rate accuracy of ±2bpm under 0.025% weak perfusion conditions
Anti-motion interference performance SpO2 measurement accuracy ±3% and pulse rate measurement accuracy ±4bpm at 0-4Hz, 0-3cm random motion or fixed frequency motion
Breathing measurement Optional
Initial output time 4s
Probe off detection Yes
Probe failure detection Yes
perfusion Index 0.02%~20%
Pulse wave Yes
Board size 32mm*18mm*3mm
Wiring methods Pad
Power supply 5V DC
Power consumption <15mA
Application Adult / Pediatric / Neonatal
Work environment temperature:0~40℃,humidity:15%~95% atmospheric pressure:79.5kPa~107.4kPa
Storage environment temperature:-20~60℃,humidity:15%~95% Non-condensing
,atmospheric pressure:79.5kPa~107.4kPa
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Infant Warmer” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Related products

Air O2 Blender 4 bamc medical ltd panipat
Compare

Air O2 Blender

Global Medicare
    • HIGH PRESSURE AIR O2 BLENDER
    • 21-100% OXYGEN CAN SELECT
    • LOW FLOW AND HIGH FLOW OUTPUT OPTION
    • 2 YEARS WARRANTY
    • MAKE IN INDIA
Add to wishlist
Read more
Quick view
ecg machine 2 bamc medical ltd panipat
ecg machine bamc medical ltd panipat
Compare

ECG Machine

Global Medicare
Add to wishlist
Read more
Quick view
Fetal Doppler bamc medical ltd panipat
Fetal Doppler bamc medical ltd panipat 3
Compare

Fetal Doppler

Global Medicare
Instructions Sonoline B Pocket Fetal Doppler is a hand-held obstetrical unit, which can be used in hospital, clinic and home for daily self-check by pregnant woman. Fetal doppler Contains components of ultrasonic signal transmitter and receiver, analog signals processing unit, FHR calculating unit, LCD display control unit etc. Sonoline B Pocket Fetal Doppler is a high performance model with (fetal heart rate) LCD digital display. It has 3 work modes: Real-time FHR display Mode, averaged FHR display mode, and manual mode. It has audio output and can be connected with earphone or recorder with audio input. Main Features -Battery status indicator -Low power inspection of the battery -Built-in speaker -Output for headphones -The probe can be changeable -Probe inspection -Backlight -Auto shut off -Support 2MHz, 3MHz, 4MHz, 5MHz, 8MHz probes -Two pieces of standard 1.5V alkaline battery available which can work no less than 10 hours Main performance. Anti-electroshock Type: Internally powered equipment 2.Anti-electroshock Degree: Type B applied part 3.LCD Display: 45 mm × 25 mm 4.FHR Measuring Range: 50 BPM ~ 240 BPM (BPM: Beat per minute) 5.Resolution: 1 BPM 6.Accuracy: ± 2 BPM 7.Power Consumption: < 0.8 W 8.Voltage: DC 3.0 V 9.Power Supply: TWO 1.5V(AA size)alkaline battery 10.Suitable Using Range: Suitable for use after the 12th week of pregnancy 11.Auto Shut-OFF: After 1 minute no signal, power off automatically Pocket Fetal doppler Probe: 1.Nominal Frequency: 2.0 MHz 2.Working Frequency: 2.0 MHz ± 10% 3.Ultrasound Output Power: P < 10 mW 4.Ultrasonic Output Intensity: Isata < 5 mW/cm2 5.Negative Peak Sound Pressure: P_ < 0.5 MPa 6.Working Mode: Continuous wave doppler Effective Radiating Area of Transducer: 208 mm2 ± 15% Physical Characteristic Dimension: (L) 135 mm × (W) 95mm × (H ) 35 mm Qualification Sonoline B:Pocket Fetal Doppler-CE/FDA
Add to wishlist
Read more
Quick view
GAS PIPELINE PROJECTS IN OT ICU AND NICU bamc medical ltd panipat
GAS PIPELINE PROJECTS IN OT ICU AND NICU bamc medical ltd panipat 2
Compare

Gas Pipeline Projects in OT ICU and NICU

Global Medicare
INDIAN,FRENCH AND USA ALL TYPE AND STANDARDS AVAILABLE
e are a high-tech enterprise mainly engaged in the development, production and marketing of medical gas engineering products. We have core technology management process, experienced market, fast and efficient manufacturing, processing capabilities, rich supporting processing and manufacturing resources. Customers are all over India , France , USA , China (including Taiwan and Hongkong), southeast Asia, Africa and other regions. Efficient technology support and high quality products have been recognized by customers. We continue working hard to provide more convenient, richer varieties and better quality, better price medical products.
\n
\n
Add to wishlist
Read more
Quick view
HFNC bamc medical ltd panipat 2
HFNC bamc medical ltd panipat 4
Compare

HFNC

Global Medicare
Add to wishlist
Read more
Quick view
menquet servo i ventilator bamc medical ltd panipat
Compare

Maquet servo I ventilator

Global Medicare
    • Maquet servo i ventilator
    • neonatal to adult universal
    • with nasal cpap
    • fully refurbished
Add to wishlist
Read more
Quick view
Medical Dry Air Compressor bamc medical ltd panipat
Compare

Medical Dry Air Compressor

Global Medicare
Medical Air compressor for ventilator and bubble cpap Compact & Modular Design having dimension 13.5” x 13”x 18.5” (LxWxH) Quiet Operation, suitable for bedside use Delivers a Flow of 50 + 10 lpm @ 25 + 5 psig Oil-free compressor motor with thermal cutout Optional digital display with alarms for added safety Optional Electronic Dryer Optional Low-Flow Model available Large locking castors for easy transport Having all international approvals & certifications – CE, IEC, etc
Add to wishlist
Read more
Quick view
shorya ventilator bamc medical ltd panipat
shorya ventilator 2 bamc medical ltd panipat
Compare

Shorya Ventilator

Global Medicare
Add to wishlist
Read more
Quick view

    Contact Us:

    If you have any question, please contact us at info@bamcmedicalltd.com

    • Khasra no 44, Medical Park, Thirana – 132113
    • 9992570002

    Categories

    Medical Equipment
    Medical Equipment Service
    Refurbished Medical Equipment
    Ventilators
    Gas Pipeline Project

    Share:
    BAMC Medical Ltd 2024
    payments
    • Menu
    • Categories
    Set your categories menu in Header builder -> Mobile -> Mobile menu element -> Show/Hide -> Choose menu
    • Home
    • Products
    • About Us
    • Contact Us
    • Wishlist
    • Compare
    • Login / Register
    Shopping cart
    Close