Infant Warmer

OPERATING MODES

  • SKINMODE:

In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.

· AIR MODE:

In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.

· MANUAL: MODE

In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 10

Compare
Add to wishlist
Category: Global Medicare
Share:
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

DISPLAY INDICATION

  • LCD:

LCD displays the following information.

  1. CurrentMode
  2. Heatingspeed
  • Alerts:Low Temp, High Temp, Probe fail
  1. Settings:Set Temp, Low Alarm, High Alarm, Manual mode timer, Calibration, Product branding
  2. APGARtimer

· 7 SEGMENT DISPLAY:

Displays current Skin and Air temperature, blinks for out of range (Low and high alarm) and clears upon probe fail.

ALERTS

  • Powerfail: Power fail indicator turns ON with sound alert (cannot be muted).
  • Probefail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp
  • Heateroverload: Heater overload indicator turns
  • Low temperature:Low alarm indicator turns ON with sound alert (can be muted). Displays
  • Hightemperature: High alarm indicator turns ON with sound alert (can be muted). Displays
  • Manualmode Time out: Short sound alert and timer flashing on

IMPORTANT INSTRUCTIONS

We recommend that you read the following instruction carefully, before using the machine/Equipment

  • Supplyvoltage should be between 220V-240V
  • Donot use the machine/Equipment when the mains cord, the plug or other components are damaged.
  • Themachine/Equipment should be handled by authorized person
  • Donot clean machine/Equipment with water or other cleaning
  • Checkheater and probe before using the
  • Donot leave baby unattended for long
  • Werecommend to use 650W
  • Newprobes or replacement probe should be calibrated before

Neonatal Pulse Oximeter/optional:

Pcb Design : BAMC Medical

Display  : 2” colour TFT

SpO2 measurement range 35%~100%
SpO2 measurement Accuracy ±2%(70%~100%)
SpO2 resolution 1%
PR measurement range 30~250bpm
PR measurement Accuracy The greater of ±2bpm
PR resolution 1%
Low perfusion performance 0.025%
Oximeter accuracy of ±2% and pulse rate accuracy of ±2bpm under 0.025% weak perfusion conditions
Anti-motion interference performance SpO2 measurement accuracy ±3% and pulse rate measurement accuracy ±4bpm at 0-4Hz, 0-3cm random motion or fixed frequency motion
Breathing measurement Optional
Initial output time 4s
Probe off detection Yes
Probe failure detection Yes
perfusion Index 0.02%~20%
Pulse wave Yes
Board size 32mm*18mm*3mm
Wiring methods Pad
Power supply 5V DC
Power consumption <15mA
Application Adult / Pediatric / Neonatal
Work environment temperature:0~40℃,humidity:15%~95% atmospheric pressure:79.5kPa~107.4kPa
Storage environment temperature:-20~60℃,humidity:15%~95% Non-condensing
,atmospheric pressure:79.5kPa~107.4kPa
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Infant Warmer” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Related products

5Liters Home Use Oxygen Concentrator bamc medical ltd panipat
Compare

5L Home Use Oxygen Concentrator

Global Medicare
Specification 1. Oxygen flow rate : 1-5LPM/MIN 2. Oxygen Concentration : 93%+3% 3. Outlet pressure : 8.5-13 psi 4. Voltage : 230V;50hz 5. Power Consumption : 320W 6. Noise :<48dB(A) 7. Wight : 16 KG. 8. Nozzle : 1 9. Size : 305mm (L) x330 mm (W) x 535 mm (H) Function 1. Running time control & calculation 2. Alarms for high/low pressure, power failure and Gas blockage. 3. Protection for over-heat and over-load. 4. Purity alarm when the oxygen purity below 82% (Optional) 5. Medical nebulization by output oxygen dual Output.
Add to wishlist
Read more
Quick view
alvin ventilator bamc medical ltd panipat
alvin ventilator 2 bamc medical ltd panipat
Compare

Alvin Ventilator

Global Medicare
Add to wishlist
Read more
Quick view
Carefusion area ventilator bamc medical ltd panipat
Compare

Carefusion avea ventilator

Global Medicare
    • refurbished carefusion avea ventilator
    • neonatal to adult ventilator
    • inbuilt turbine and compressor option also
    • vg mode
    • nasal cpap mode included
    • 1 year warranty on condition
    • spare parts available
    • Can whats app for sale and service
    • 24*7 4500 support person in india and 600+ outside india.
Add to wishlist
Read more
Quick view
HFNC bamc medical ltd panipat 2
HFNC bamc medical ltd panipat 4
Compare

HFNC

Global Medicare
Add to wishlist
Read more
Quick view
ICU Equipments service n Spare parts bamc medical ltd panipat 2
ICU Equipments service n Spare parts bamc medical ltd panipat 13
Compare

ICU Equipments service n Spare parts

Global Medicare
BIGGEST SERVICE CENTRE ACROSS INDIA We BAMC Medical Public Ltd also known as global medicare panipat. With manufacturing of medical equipments we also provide service and spare parts for the many reputed brand for example Drager, Maquet, GE, Hamilton, carefusion, Datascope, Global Medicare, BAMC Medical, Contec, mindray, etc. We have all over around 4500 dealers across India and 700 customers out of India .
Add to wishlist
Read more
Quick view
ICU Ventilator bamc medical ltd panipat 3
ICU Ventilator bamc medical ltd panipat 2
Compare

ICU Ventilator

Global Medicare
Powerful and optimal ventilation modes The Dual PAP ventilation mode is able to provide the patient with biphasic horizontal pressure (high pressure phase and low pressure phase). With the suitable pressure, this perfect modes not only exercises the patient's breathing muscles, but also reduces the reliance on the ventilator. Freeflow is an advanced closed-loop control technology with square wave pattern and decelerating flow pattern. Under the square wave pattern, the patient is able to breathe spontaneously in the inspiratory phase, while under the decelerating flow pattern, the system is able to adjust the flow rate according to the patient's compliance and resistance changes. It means this advanced mode greatly reducing the use of sedatives and muscle relaxants, and has obvious effects on patients with atelectasis, ARDS, acute pulmonary edema, and asthma. Comprehensive and visible monitoring function With 15 inch color touch screen, the Boaray 5000D is able to show 4 waveforms and 2 loops simultaneously. And it can monitor more than 20 important parameters to help you know the patient status in    anytime. Free breathing technology for breathing freely The free breathing technology can release excessive pressure caused by a cough or active exhalation, to ensure patient safety and make breathing more comfortable. Features: Vt range: 20-2000ml; Applicable to adult, pediatric and infant Ventilation modes: VCV, PCV, SIMV(P)+PS, SIMV(V)+PS, SPONT/CPAP, Sigh, PRVC, DualPAP, NPPV, Manual, Standby Weaning parameter (RSB, P0.1, NIF) 15 inch TFT touch screen & big front view for easy observation Simultaneous display of 4 waveforms and 2 loops CO2 and SpO2 monitoring (optional) Synchronized nebulizer and air compressor (optional) Expiratory valve could be taken off for autoclavable disinfection to avoid cross-infection Active exhalation valve with anti-condensation design World leading brands of key components of ventilator ensure high accuracy and stable performance Advanced proportional solenoid technology realize accurate ventilation control Multi-safety mechanism and three-priority alarm of visual and audio for different risks
Add to wishlist
Read more
Quick view
Patient Monitor bamc medical ltd panipat
Compare

Patient Monitor

Global Medicare
Application Range: Adult/Pediatric/Neonatal/Medicine/Surgery Operating Room/lCU/CCU Display: 8’’real color TFT screen Resolution:800*600 One alarm indicator(yellow/red) One working indicator(green) One battery charge state indicator(green) Three modes in accordance with the alarm state Power Requirements: AC:100-240V,50Hz/60Hz DC:Built-in rechargeable battery Battery:4000mA 11.1V lithium battery 2hoperatingafter full charge one piece)
Add to wishlist
Read more
Quick view
Transport Ventilator bamc medical ltd panipat
Compare

Transport Ventilator

Global Medicare
BAMC Transport Pro 510s
Adult, Child, Infant (>3.5 kg) A/C-V with Sigh SPONT/PSV Apnea back-up ventilation
A/C-P CPAP Manual breath 0-2000 mL 0-50 cmH2O 0-30 cmH2O 2-30 L/min 4:1-1:10 40-100 % F-T
n510S is a universally used model. Not only for emergency ventilation, but also it is suitable for ideal transport ventilation. The circumstances include on-site emergency treatment, pre-hospital transport, inter- hospital transport, and even intra-hospital transport.
Add to wishlist
Read more
Quick view

    Contact Us:

    If you have any question, please contact us at info@bamcmedicalltd.com

    • Khasra no 44, Medical Park, Thirana – 132113
    • 9992570002

    Categories

    Medical Equipment
    Medical Equipment Service
    Refurbished Medical Equipment
    Ventilators
    Gas Pipeline Project

    Share:
    BAMC Medical Ltd 2024
    payments
    • Menu
    • Categories
    Set your categories menu in Header builder -> Mobile -> Mobile menu element -> Show/Hide -> Choose menu
    • Home
    • Products
    • About Us
    • Contact Us
    • Wishlist
    • Compare
    • Login / Register
    Shopping cart
    Close